airconditioninginspection.org
Air Conditioning Inspection of Split Systems
http://www.airconditioninginspection.org/split-systems.html
Order Now - Free Quote. Order Now - Free Quote. TM44 air conditioning inspection of individual split systems:. In split systems a single outdoor unit called condenser containing refrigeration and heat rejection equipment is connected to an individual indoor unit called evaporator delivering cooling or heating. These may also be called ‘split package units’. These types of systems are categorised as Level 3. In TM 44 Legislation. And simple air conditioning inspection. Code for Sustainable Homes 2011.
airconditioninginspection.org
Air conditioning certificates, Air conditioning inspectors
http://www.airconditioninginspection.org/air-con-inspections.html
Order Now - Free Quote. Order Now - Free Quote. TM44 Air Conditioning Inspection report:. According to European Performance of Buildings Directive (EPBD) guidelines, it is mandatory for all air Conditioning systems with effective rated capacity of more than 12kW to have regular inspections carried out by an accredited air conditioning inspector. For all systems, they must have had their first inspection done by the 4th of January 2011. 1 Why TM44 air conditioning inspections are required? Replacement of ...
airconditioninginspection.org
Air Conditioning Inspections of Chillers and Air handling units
http://www.airconditioninginspection.org/chillers.html
Order Now - Free Quote. Order Now - Free Quote. Chiller units, Air Handling Units and Fan Coil Units). Centralised systems: in which refrigeration equipment delivers cooling through air handling unit(s) and/or pumped water circuits. These may include constant volume (CV) systems, variable air volume (VAV) systems, systems using fan coil units (FCUs) or induction units, and systems using active or passive chilled beams. Centralised cooled water systems:. Active terminal units would include fan coil units,...
airconditioninginspection.org
Order Air Conditioning Inspection Now
http://www.airconditioninginspection.org/order-now.html
Order Now - Free Quote. Order Now - Free Quote. Order Now Form - Free Quotes. Please fill in the boxes below and press submit once finished. It is necessary fill up all the boxes with (*) sign . Project name or number*:. Type of Certification needed:*. School, College, University. Hospital, Nursing home. Museum and Art Gallary. Gross Internal Area:* (of all buildings in total). Have you got floor plans? What Kind of cooling system do you have? What is the cooling load capacity of your systems in total?
airconditioninginspection.org
About Air Conditioning Inspections
http://www.airconditioninginspection.org/about-us.html
Order Now - Free Quote. Order Now - Free Quote. Is a trading name of Future By Energy . We are nationwide service provider for TM44 Air conditioning inspections, Air conditioning surveys and Air conditioning certificate reports. Are experienced energy assessors and building design engineers, providing professional expertise in energy assessments for buildings and strategic energy advice. We have experience in a wide range of building types in commercial sectors. Energy Performance Certificates (EPCs).
airconditioninginspection.org
Air conditioning inspections of Package Unit systems
http://www.airconditioninginspection.org/package-unit.html
Order Now - Free Quote. The indoor and outdoor units are both contained in a self-contained ‘unitary’ housing, often installed as a ‘through the wall’ unit. The unit may be reversible allowing operation as a heat pump, or electric resistance heating may be included. These types of systems are categorised as Level 3. And simple procedure generally considered suitable for these systems. Code for Sustainable Homes 2011. Code for Sustainable Homes Assessor. Code for Sustainable Homes Level 3.
airconditioninginspection.org
Air conditioning inspections of VRF and VRV Systems
http://www.airconditioninginspection.org/vrf-systems.html
Order Now - Free Quote. Order Now - Free Quote. TM44 air conditioning inspection of VRF, VRV and Multi Split Systems:. In Multi-split systems one or more ‘outdoor units’ containing refrigeration and heat rejection equipment are each connected to a number of ‘indoor units’ delivering cooling. These may also be called multi-split package units, and include variable refrigerant flow (VRF-VRV) systems. These types of systems are categorised generally as Level 4. In TM 44 Legislation.
SOCIAL ENGAGEMENT