allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: June 2010
http://allispossibleblog.blogspot.com/2010_06_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Tuesday, June 8, 2010. SIEBEL IF ROW STAT IN PROGRESS due to SBL-EIM-00107. IF ROW STAT shows IN PROGRESS after EIM process has completed. DataDirect][ODBC Oracle driver][Oracle]ORA-00001: unique constraint (SIEBEL.S LOY TXN U1) violated. Error SBL-EIM-00107: ODBC error 23000:. DataDirect][ODBC Oracle driver][Oracle]ORA-00001: unique constraint. SIEBEL.S LOY TXN U1) violated. ODBC error 23000: [Dat...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: EIM IF_ROW_STAT: REQUIRED_COLS
http://allispossibleblog.blogspot.com/2011/04/eim-ifrowstat-requiredcols.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Monday, April 4, 2011. EIM IF ROW STAT: REQUIRED COLS. After executing EIM, the IF ROW STAT field becomes REQUIRED COLS and rows are not imported. We get REQUIRED COLS in IF ROW STAT when one or more of the required columns are not populated in EIM table. Extract from log file follows:. EIMError EIMErrorSubEvent 0 000000034d8c0740:0 2011-03-25 11:53:21. EIMError EIMErrorSubEvent 0 000000034d8c0740:...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: May 2010
http://allispossibleblog.blogspot.com/2010_05_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Thursday, May 27, 2010. Informatica: Error using PMCMD. The connect request failed because the client application is trying to connect to server type [pmserver]. Repository server accepts only requests for server types REPSERVER and REPAGENT. Links to this post. Informatica: Error when validating source qualifier query. 1) Ensure that the query is returning the same number of columns as there are p...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: Copying a datagridview
http://allispossibleblog.blogspot.com/2011/03/copying-datagridview.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Sunday, March 20, 2011. The function below will make a copy of a datagridview. Its in C#. Private void copyDGV(DataGridView dgvOriginal, DataGridView dgvCopy). DgvCopy.Columns.Clear();. DgvCopy.Rows.Clear();. Foreach (DataGridViewColumn col in dgvOriginal.Columns). DgvCopy.Columns.Add( DataGridViewColumn)col.Clone() ;. DataGridViewRow dgvr = new DataGridViewRow();. Int nColIndex = 0;.
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: August 2010
http://allispossibleblog.blogspot.com/2010_08_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Friday, August 6, 2010. Siebel escript Associative Array. Associative Arrays in Siebel Escript, allow us to use strings instead of numbers in the indices of the array. For example, if we have an associative array called "myArray" whereby we store the age of a few contacts, we can fill it with elements as follows:. Let's say we fill in our associative array, myArray, using a for loop as follows:.
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: March 2011
http://allispossibleblog.blogspot.com/2011_03_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Monday, March 28, 2011. SBL-EIM-00205: NULL target table for relation! When executing an EIM procress you get the error: SBL-EIM-00205: NULL target table for relation! Followed by the error SBL-EIM-00205: Failed to load the application dictionary. In your EIM log file (log level set to 5) you can see the following:. Try the following to resolve the issue:. 1) Please try deleting/inactivating the co...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: April 2011
http://allispossibleblog.blogspot.com/2011_04_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Monday, April 4, 2011. EIM IF ROW STAT: REQUIRED COLS. After executing EIM, the IF ROW STAT field becomes REQUIRED COLS and rows are not imported. We get REQUIRED COLS in IF ROW STAT when one or more of the required columns are not populated in EIM table. Extract from log file follows:. EIMError EIMErrorSubEvent 0 000000034d8c0740:0 2011-03-25 11:53:21. EIMError EIMErrorSubEvent 0 000000034d8c0740:...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: February 2009
http://allispossibleblog.blogspot.com/2009_02_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Friday, February 13, 2009. Using Computers as an aid in the teaching and learning process - Part Two. You will require Microsoft Excel to be able to view and modify the spreadsheet. In the sample excel sheet, I have made use of functions such as SUM, AVERAGE, RANK. Use of CONDITIONAL FORMATTING can also be made to, for example, highlight marks of students below the passing mark. Links to this post.
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: SBL-EIM-00205: NULL target table for relation!
http://allispossibleblog.blogspot.com/2011/03/sbl-eim-00205-null-target-table-for.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Monday, March 28, 2011. SBL-EIM-00205: NULL target table for relation! When executing an EIM procress you get the error: SBL-EIM-00205: NULL target table for relation! Followed by the error SBL-EIM-00205: Failed to load the application dictionary. In your EIM log file (log level set to 5) you can see the following:. Try the following to resolve the issue:. 1) Please try deleting/inactivating the co...
allispossibleblog.blogspot.com
all is possible - Siebel, Informatica and .Net: April 2010
http://allispossibleblog.blogspot.com/2010_04_01_archive.html
All is possible - Siebel, Informatica and .Net. Where there is a will, there is a way. believe in yourself. Thursday, April 29, 2010. This operation is not available for read-only field 'FIELDNAME'. (SBL-DAT-0042). Hope that this article helps you solve your issue and save some time. Links to this post. Subscribe to: Posts (Atom). If you are interested with fundamentals of life, then visit the following blogs. Be for ever positive.